              TENS/EMS

              FDES108

              TENS & EMS DualPad

              FDES108

              For program of TENS mode

              To be used for temporary relief of pain associated with

              sore and aching muscles due to strain from exercise or

              normal household work activities.


              For program of EMS mode

              To be used to stimulate healthy muscles in order to improve

              and facilitate muscle performance.



              Suggested retail price:$

              Features
              Intended use
              For program of TENS mode
              To be used for temporary relief of pain associated with sore and aching muscles due to strain
              from exercise or normal household work activities.


              For program of EMS mode
              To be used to stimulate healthy muscles in order to improve and facilitate muscle performance.

              What is Electrical Stimulator and what can it do?
              Digital TENS/EMS belongs to the group of electrical stimulation systems. It has two basic functions,
              which can be used in combination.
              1. Electrical stimulation to nerve tracts (TENS)
              2. Electrical stimulation to muscle tissue (EMS)
              It has various versatile functions in order to increase general well-being, alleviate pain, maintain physical
              fitness,relaxation, and revitalize muscles and combat fatigue. You can either select these functions from
              preset programs or determine them yourself according to your requirements.

              The operation principle of electrical stimulation equipment is based on simulating the body's own pulses
              which are transmitted transcutaneous to nerve or muscle fibers by means of electrodes. The electrodes can
              thereby be attached to many parts of the body, whereby the electrical stimuli are safe and practically
              painless. You will merely feel a gentle prickling or vibrating sensation in some applications. The electrical
              pulses transmitted to the tissue affect the transmission of stimulation in nerve conductions as well as
              Neuron and muscle tissue in the field of application.

              Electrical stimulation does not replace regular exercising of the muscle, but is able to reasonably supplement
              the effect thereof

              TENS, Transcutaneous Electrical Nerve Stimulation, means electrical stimulation of nerves through the skin. It is a
              non-medical method of treating pain from certain causes. TENS uses tiny electrical impulses sent through the skin
              to nerves to modify your pain perception. TENS does not cure any physiological problem; it only helps control the
              pain. TENS does not work for everyone; however, in most patients it is effective in reducing or eliminating the pain,
              allowing for a return to normal activity.



              TENS is clinically tested and approved with the following applications:



              EMS, Electrical Muscle Stimulation, is a widespread and generally recognized method and has been
              used for years in sports and rehabilitation medicine. In the sports and fitness field, one of the uses of EMS
              is as a supplement to conventional muscle training, in order to increase the efficiency of muscle groups
              and adapt physical proportions to the desired aesthetic results. EMS application goes in two directions. On
              one hand, a targeted strengthening of musculature can be produced (Activating application) and on the
              other hand a relaxing, resting effect can also be achieved (relaxing application)



              Active application includes the following:




              Relaxing application includes the following:







              Basic Information
              hannel Dual, isolated between output channels
              Operating conditions 5°C to 40°C (41°F to 104°F) with a relative humidity of 30%-85%,atmospheric pressure from 70 to 106 kPa
              Storage conditions -10°C to 55°C (14°F to 122°F) with a relative humidity of 20%-93%,atmospheric pressure from 70 to 106 kPa
              Power supply DC 4.5V , 1.5x3(AAA) battery
              DC capacity, Maximum Amplitude and Load Impedance Equipment output DC capacity: 0,
              Maximum output one-way peak value voltage 40V±20%,
              Load Impedance: 500 Ohms
              Power save time I Wait<10mA
              Power Off Current I Off<150uA
              Dimensions 110×59.5×30(mm)(L×W×H)
              Weight 45g(Without battery)
              Tolerance There may be a ±10% tolerance of all setting (frequency, pulse width) and ±20% tolerance of output of intensity.
              Electrode Detection Function The amplitude level will be reset to 0mA when the amplitude level is 10mA or greater and an open circuit at either channel is detected.